Breas Vivo 30 BiPAP Machine


Description
Breas Vivo 30 Bi-PAP device is a value powerful, properly relied on, non-invasive, superior, and clinically reliable ventilation assist for the patient with respiratory problems. Pressure manipulate and stress assist modes play critical function in Bi-Level ventilator to offer non-invasive respiratory assist. It facilitates patients inside the health center as well as at home, providing breathing assist. Vivo 30 has eSync technology internal which it synchronizes easily with the patient’s respiratory attempt. The device responds at once and delivers the specified pressure in step with the affected person’s demand for brand spanking new breath. An intuitive consumer-interface of Vivo 30 enables each the affected person and the health practitioner to modify the favored settings. It has an integrated heated humidifier which helps to moisten the air. Features like huge, easy-to-study display with simple menu shape, and again-mild, huge and easy-to-use buttons with back-mild, and constructed in alarm clock make it a consumer-friendly tool to be a part of any domestic environment. The device is designed for a extensive variety of masks and works on three ventilation modes. It can be operated on a flexible DC energy options. It is a strong unit with small footprint and clean to hold case. You can buy or rent the tool from Nightingales for clean and comfortable respiration help.

Specifications for Breas Vivo 30 BiPAP Machine
Ventilation modes: PSV (Pressure Support Ventilation), PCV (Pressure Control Ventilation), CPAP (Continuous Positive Airway Pressure)

Device modes: Clinical & CPAP

IPAP/EPAP: four to 30 cmH2O / 2 to twenty cmH2O

CPAP: 4 to twenty cmH2O

Breath fee: 4 to forty BPM (PVC and PSV mode)

Inspiration time: zero.Three to 5 sec

Rise time: 1 to 9

Inspiratory cause (eSync): 1 to nine, off

Expiratory trigger: 1 to 9

Ramp function: 10-60 min

Humidification: 1 to nine

Audible alarm: 1 to nine

Maximum waft: >2 hundred liters/min

Max restrained stress at some point of single fault circumstance: CPAP: 30 cm H2O

PCV, PSV: 60 cm H2O

Max waft in CPAP mode: 1/three of max strain: a hundred bipap machine price and ten l/min 2/three of max strain: a hundred and fifty l/min max strain: 155 l/min

Breathing resistance under unmarried fault condition: 4 cmH2O at 30 l/min, 6 cmH2O at 60 l/min

Noise degree (at 10 cmH2O) less than 30 dB(A)

bar graph and virtual data: zero to 30 cmH2O

Calculated tidal volume accuracy: +/- 20%

Leakage calculation accuracy: +/- 20%

Total breath fee BPM (breath per minute): I/E ratio 1:10 to 10:1

Audible alarm degree: 45 to 76 dB(A)

Mains supply/External battery: 100 to 240 V AC / 12/24 V DC

Recommended masks leakage: 20 to 40 l/min at 10 cmH2O

Air outlet: 22 mm male conical general connector


Leave a Reply

Your email address will not be published. Required fields are marked *